RAE Systems MiniRAE 3000 & MiniRAE Lite Calibration Kit

$486.00
SKU:
RAE-Calkit-MiniRAE (3000/LITE)
Weight:
5.00 LBS
Shipping:
Calculated at Checkout
Buy a MiniRAE 3000 and MiniRAE Lite calibration kit with 100 ppm isobutylene gas, regulator, tubing, calibration adapter, and carrying case.
See full description

Important Delivery Information:

Orders can only be expedited if the Next Day Air shipping option is selected. The standard lead time for NON Next Day Air orders is 3 business days.

Calibration Kit for RAE Systems MiniRAE 3000 and MiniRAE Lite PID Monitors

The RAE Systems MiniRAE 3000 and MiniRAE Lite Calibration Kit provides the essential supplies needed to calibrate compatible portable PID (photoionization detector) gas monitors used for volatile organic compound (VOC) detection. This calibration kit includes 100 ppm isobutylene calibration gas, a gas regulator, calibration adapter with tubing, and a carrying case for convenient storage and transportation.

Manufactured by Intermountain Specialty Gases, this calibration kit is designed to support routine calibration and maintenance of RAE Systems MiniRAE 3000 and MiniRAE Lite VOC monitors.

Calibration Kit Contents

Each RAE Systems PID calibration kit includes: 

  • 100 ppm Isobutylene Calibration Gas: Standard calibration gas for compatible PID VOC detectors.
  • Gas Regulator: Controls calibration gas delivery during the calibration process.
  • Calibration Adapter and Tubing: Provides the connection between the calibration gas cylinder and gas monitor.
  • Carrying Case: Keeps calibration components organized and protected during storage and transportation.

Product Specifications

 

SpecificationDetails
Product Type PID Gas Monitor Calibration Kit
Compatible Instruments RAE Systems MiniRAE 3000 and MiniRAE Lite
Calibration Gas 100 ppm Isobutylene
Cylinder Size 34-liter steel cylinder
Gas Manufacturer Intermountain Specialty Gases
Gas Shelf Life 48 months
Includes Gas, regulator, calibration adapter, tubing, carrying case
TG Technical SKU RAE-Calkit-MiniRAE (3000/LITE)

 

Why Calibrate Your RAE Systems PID Gas Monitor?

Routine calibration helps verify that portable VOC gas monitors respond properly to known gas concentrations. Using the appropriate calibration gas and compatible calibration accessories helps maintain measurement reliability and supports routine instrument maintenance.

The MiniRAE 3000 and MiniRAE Lite are portable photoionization detectors designed to measure volatile organic compounds (VOCs) in environmental monitoring, industrial hygiene, leak detection, and hazardous materials applications.

Always follow the manufacturer's calibration procedures and recommended calibration intervals for your specific instrument.

Buy RAE Systems Calibration Kits from TG Technical Services

TG Technical Services supplies calibration gas, gas monitor calibration kits, regulators, and accessories for leading gas detection manufacturers. Whether you need a calibration kit for a MiniRAE 3000 or MiniRAE Lite PID monitor, our team can help you find the appropriate calibration supplies for your equipment.

Order your RAE Systems MiniRAE calibration kit from TG Technical Services to support routine VOC monitor calibration and maintenance.

Frequently Asked Questions

1. What gas is used to calibrate the RAE Systems MiniRAE 3000 and MiniRAE Lite? 

Both instruments use 100 ppm isobutylene as the standard span calibration gas, according to the RAE Systems handheld PID monitor user guide. 

2. Is this calibration kit compatible with both the MiniRAE 3000 and MiniRAE Lite? 

Yes. This kit is listed for use with both RAE Systems MiniRAE 3000 and MiniRAE Lite PID monitors. Confirm your instrument model and calibration connection before ordering. 

3. What is isobutylene calibration gas used for? 

Isobutylene is a reference gas commonly used to calibrate photoionization detectors (PIDs). It provides a known concentration against which the instrument's response can be checked and adjusted. 

4. How often should a MiniRAE PID monitor be calibrated? 

Calibration frequency depends on the instrument's operating conditions, use, and applicable workplace procedures. Perform calibration according to the manufacturer's recommendations and your facility's safety program. A failed bump test or accuracy check may indicate that a full calibration is needed. 

5. Is a bump test the same as calibration? 

No. A bump test checks whether the monitor responds to gas and activates its alarms. Calibration adjusts the instrument's readings against a known reference gas. One does not replace the other. 

6. Does this kit include the MiniRAE gas monitor? 

No. This is a calibration kit for compatible RAE Systems PID monitors. The gas monitor is sold separately. 

7. Can this calibration kit be used with other RAE Systems instruments? 

Do not assume compatibility with other RAE Systems models. Different instruments may require different calibration gas concentrations, regulators, adapters, or procedures. Check the specific instrument's user guide before using calibration equipment.

 

 

 

24 Month