Honeywell E3Point CO & NO2 Calibration Kit | 60L

$275.00
Weight:
10.00 LBS
Shipping:
Calculated at Checkout
Buy a complete Honeywell E3Point CO and NO2 calibration kit. Includes 60L calibration gas, regulator, adapter, tubing and carrying case.
See full description

Honeywell E3Point CO and NO2 Gas Monitor Calibration Kit – Complete 60-Liter Kit

Important Delivery Information:

Orders can only be expedited if the Next Day Air shipping option is selected. The standard lead time for NON Next Day Air orders is 3 business days.

Includes everything needed to calibrate the instrument: Carrying Case, Regulator, Calibration Adapter with tubing, Calibration Gas

Brand: Intermountain Specialty Gases

Bottle Size:   60 Liters (you will probably get 100 calibrations out of a bottle of gas)

Concentration (CO - Carbon Monoxide):      200 ppm (Shelf Life: 48 Months)

Concentration (NO2 - Nitrogen Dioxide):     5 ppm (Shelf Life: 6 Months)

Calibration Instructions are in the manual and are available from this link:

www.honeywellanalytics.com/en/products/E3Point

Additional Details: Honeywell E3Point CO and NO2 Gas Monitor Calibration Kit – Complete 60-Liter Kit

Maintain the accuracy and reliability of your Honeywell E3Point fixed gas detection system with this complete calibration kit for Carbon Monoxide (CO) and Nitrogen Dioxide (NO2) sensors.

The Honeywell E3Point calibration kit includes the calibration gas and essential accessories needed to perform routine gas detector calibration. Each kit comes with a 60-liter calibration gas cylinder, regulator, calibration adapter with tubing, and a protective carrying case.

Designed for commercial buildings, parking garages, mechanical rooms, loading docks, boiler rooms, and other facilities using Honeywell E3Point gas detection systems, this complete calibration kit provides a convenient solution for routine gas detector maintenance.

Calibration Kit Includes: 

  • 60-liter calibration gas cylinder
  • Gas regulator
  • Calibration adapter
  • Calibration tubing
  • Protective carrying case

Calibration Gas Specifications

Carbon Monoxide (CO) Calibration Gas 

  • Concentration: 200 ppm CO
  • Cylinder size: 60 liters
  • Shelf life: 48 months
  • Estimated yield: Approximately 100 calibrations per cylinder

Nitrogen Dioxide (NO2) Calibration Gas 

  • Concentration: 5 ppm NO2
  • Cylinder size: 60 liters
  • Shelf life: 6 months
  • Estimated yield: Approximately 100 calibrations per cylinder

Actual calibration yield depends on regulator flow rate, gas application time, and the manufacturer's calibration procedure.

Compatible Gas Detection Equipment

This calibration kit is designed for Honeywell E3Point fixed gas monitors equipped with: 

  • Carbon Monoxide (CO) sensors
  • Nitrogen Dioxide (NO2) sensors
  • Compatible remote CO and NO2 sensor configurations

Select the appropriate calibration gas and additional gas option based on your installed E3Point sensor configuration.

Common Applications

Honeywell E3Point gas monitors are commonly installed in: 

  • Parking garages and enclosed parking structures
  • Commercial buildings
  • Mechanical and boiler rooms
  • Loading docks
  • Transportation facilities
  • Commercial ventilation systems
  • Industrial and institutional facilities

Why Choose TG Technical Services? 

TG Technical Services specializes in gas detection equipment, calibration gases, calibration kits, and replacement accessories from leading manufacturers, including Honeywell, RKI Instruments, RAE Systems, and BW Technologies. 

Our Honeywell E3Point calibration kits provide the gas and accessories needed to support routine maintenance and calibration programs for fixed gas detection systems.

Order your Honeywell E3Point CO and NO2 calibration kit from TG Technical Services and keep your gas detection equipment properly maintained.

Frequently Asked Questions About Honeywell E3Point Calibration Kits 

How often should a Honeywell E3Point gas monitor be calibrated?

According to the Honeywell E3Point standalone gas monitor user manual, the monitor should be bump tested or gas tested every 6 months and calibrated every 12 months. More frequent testing may be necessary depending on operating conditions, environmental exposure, and facility safety requirements.

How often should a Honeywell E3Point gas detector be bump tested?

Honeywell recommends bump or gas testing E3Point standalone monitors every 6 months. A bump test verifies that the sensor responds to the target gas and that the alarm system functions properly.

What is the difference between a bump test and a calibration?

A bump test exposes the gas sensor to a known concentration of test gas to verify sensor response and alarm operation. Calibration adjusts the monitor's readings to match a known reference gas concentration. A successful bump test does not replace scheduled calibration.

What calibration gas is used for Honeywell E3Point CO sensors?

The Honeywell E3Point CO calibration kit uses 200 ppm carbon monoxide calibration gas. This kit includes a 60-liter cylinder with a stated shelf life of 48 months.

What calibration gas is used for Honeywell E3Point NO2 sensors?

The Honeywell E3Point NO2 calibration kit uses 5 ppm nitrogen dioxide calibration gas. The 60-liter cylinder has a stated shelf life of 6 months.

Can I calibrate both CO and NO2 sensors with this kit?

Yes, the product offers CO and NO2 calibration gas options. Customers can select the appropriate gas and additional gas option to match their installed sensor configuration. Each sensor must be calibrated using the appropriate gas and the manufacturer's specified procedure.

How many calibrations can I get from a 60-liter calibration gas cylinder?

A 60-liter calibration gas cylinder is estimated to provide approximately 100 calibrations. Actual yield depends on gas flow rate, application time, and calibration procedure.

What is included in the Honeywell E3Point calibration kit?

The complete kit includes a 60-liter calibration gas cylinder, gas regulator, calibration adapter with tubing, and carrying case.

How long does Honeywell E3Point calibration gas last?

The listed carbon monoxide calibration gas has a 48-month shelf life. The nitrogen dioxide calibration gas has a 6-month shelf life. Always check the cylinder expiration date before performing a calibration.

Why is routine calibration important for fixed gas monitors?

Routine calibration helps ensure that fixed gas detection systems provide accurate gas concentration readings and respond appropriately to hazardous gas conditions. Proper maintenance is especially important in parking garages, commercial buildings, mechanical rooms, and other enclosed environments where carbon monoxide and nitrogen dioxide can accumulate.

Where can I purchase Honeywell E3Point calibration gas and kits?

TG Technical Services offers complete calibration kits and calibration gas for Honeywell E3Point fixed gas monitors, including CO, NO2, oxygen, methane, propane, and hydrogen sensor configurations.