RKI Instruments S2 Series Fixed Gas Sensors and Transmitters
RKI Instruments
- SKU:
- 65-2405RK
- Weight:
- 2.00 LBS
- Shipping:
- Calculated at Checkout
RKI Instruments S2 Series Fixed Gas Sensors and Transmitters
The RKI Instruments S2 Series Fixed Gas Sensors and Transmitters provide reliable, continuous monitoring of combustible gases, oxygen, hydrogen, carbon monoxide, hydrogen sulfide, carbon dioxide, and a variety of toxic gases. Designed for industrial fixed gas detection systems, the S2 Series combines proven sensor technology with a linear 4–20 mA output for integration with compatible gas monitoring controllers, PLCs, and DCS systems.
Available in multiple gas detection configurations, the RKI S2 Series offers catalytic bead, infrared, galvanic, and electrochemical sensor technologies. Select models feature explosion-proof construction for hazardous industrial environments, while optional configurations provide additional flexibility for non-hazardous locations.
Key Features of the RKI S2 Series
-
Continuous fixed gas detection for industrial applications.
-
Available for combustible gases (LEL), oxygen (O2), hydrogen (H2), carbon monoxide (CO), hydrogen sulfide (H2S), and carbon dioxide (CO2).
-
Additional toxic gas detection options, including ammonia (NH3), chlorine (Cl2), chlorine dioxide (ClO2), arsine (AsH3), hydrogen cyanide (HCN), phosphine (PH3), and sulfur dioxide (SO2).
-
Linear 4–20 mA analog output.
-
Catalytic bead and infrared sensing technologies for combustible gas detection.
-
Infrared sensing technology for selected combustible gases and carbon dioxide.
-
Electrochemical plug-in sensors for selected toxic gases.
-
Patented water-repellent coating on applicable sensor assemblies.
-
Explosion-proof transmitter configurations available.
-
Optional stainless steel junction box for corrosive environments.
-
Optional splash guard for installations exposed to water or heavy moisture.
-
Designed for indoor and outdoor fixed gas monitoring applications.
Available Gas Detection Configurations
The RKI S2 Series can be configured for a variety of gas monitoring applications.
Combustible Gas Detection
-
LEL combustible gas
-
Hydrogen-specific LEL
-
Methane (CH4)
-
Hydrocarbons
Oxygen and Common Toxic Gas Detection
-
Oxygen (O2)
-
Hydrogen sulfide (H2S)
-
Carbon monoxide (CO)
-
Hydrogen (H2), including ppm detection
-
Carbon dioxide (CO2)
Additional Toxic Gas Detection
-
Ammonia (NH3)
-
Arsine (AsH3)
-
Chlorine (Cl2)
-
Chlorine dioxide (ClO2)
-
Hydrogen cyanide (HCN)
-
Phosphine (PH3)
-
Sulfur dioxide (SO2)
-
Nitrogen dioxide (NO2)
Gas availability, measuring range, sensor technology, and hazardous-location approvals vary by model. Select the appropriate sensor configuration for your application.
Electrical Output and Controller Compatibility
RKI Instruments S2 Series transmitters provide a linear 4–20 mA analog output for continuous gas concentration monitoring. This output allows the transmitter to communicate measured gas concentrations to compatible industrial gas monitoring controllers and control systems.
The S2 Series is designed to interface with the following RKI Instruments controllers:
-
RKI Beacon 110
-
RKI Beacon 200
-
RKI Beacon 410A
-
RKI Beacon 800
The S2 Series can also interface with compatible programmable logic controllers (PLCs) and distributed control systems (DCSs).
Important: The S2 is a gas sensor/transmitter, not a direct-connect sensor. Verify the required power supply, wiring configuration, input compatibility, and electrical requirements for the selected gas model and controller.
Sensor Technology and Construction
The RKI S2 Series uses different sensing technologies depending on the gas being monitored.
-
Catalytic Bead: Used for combustible gas detection in applicable LEL configurations.
-
Infrared (IR): Available for selected combustible gases, methane, hydrocarbons, and carbon dioxide.
-
Galvanic Cell: Used in applicable oxygen detection configurations.
-
Electrochemical: Used for carbon monoxide, hydrogen sulfide, and selected toxic gas detection applications.
-
Metal Oxide Semiconductor: Used in specific hydrogen detection configurations.
Explosion-proof models feature protective housings and flame arrestors for applicable hazardous-location installations. Optional stainless steel junction boxes and splash guards are available for demanding environments.
Industrial Applications
The RKI Instruments S2 Series is suitable for fixed gas monitoring applications in a variety of industries, including:
-
Oil and gas production facilities
-
Petrochemical plants and refineries
-
Chemical processing and storage facilities
-
Water and wastewater treatment plants
-
Offshore drilling platforms
-
Manufacturing facilities
-
Steel and automotive industries
-
Pulp and paper mills
-
Gas and electric utilities
-
Parking garages
RKI Instruments S2 Series Product Specifications
| Specification | Description |
|---|---|
| Product Type | Fixed gas sensor/transmitter |
| Manufacturer | RKI Instruments |
| Output Signal | Linear 4–20 mA |
| Gas Detection | LEL, O2, H2, CO, H2S, CO2 and selected toxic gases |
| Sensor Technologies | Catalytic bead, infrared, galvanic, electrochemical and metal oxide semiconductor |
| Installation | Indoor or outdoor, depending on model |
| Enclosure | Explosion-proof or other model-specific configurations |
| Junction Box | Optional stainless steel configuration |
| Moisture Protection | Patented water-repellent coating on applicable models; optional splash guard |
| Controller Compatibility | RKI Beacon 110, 200, 410A and 800 |
| Other Interfaces | Compatible PLC and DCS systems |
| Manufacturer Warranty | One year on materials and workmanship |
Specifications, measuring ranges, operating temperatures, power requirements, approvals, and wiring configurations vary by selected gas and sensor model. Consult the manufacturer's documentation for the exact configuration.
Frequently Asked Questions About RKI S2 Series Gas Sensors and Transmitters
1. What gases can the RKI S2 Series detect?
The RKI S2 Series is available for combustible gases (LEL), oxygen, hydrogen, carbon monoxide, hydrogen sulfide, carbon dioxide, and several toxic gases, including ammonia, chlorine, chlorine dioxide, arsine, hydrogen cyanide, phosphine, and sulfur dioxide. Availability depends on the selected sensor model.
2. Does the RKI S2 Series provide a 4–20 mA output?
Yes. RKI S2 Series transmitters provide a linear 4–20 mA analog output for communicating gas concentration measurements to compatible controllers and industrial control systems.
3. Is the RKI S2 compatible with the Beacon 800?
Yes. RKI Instruments identifies the S2 Series as compatible with the Beacon 800, as well as Beacon 110, Beacon 200, and Beacon 410A controllers. The Beacon 800 uses transmitter-style gas detection inputs, making the S2 4–20 mA transmitter configuration an appropriate option.
4. Is the RKI S2 Series explosion-proof?
Explosion-proof configurations are available for selected S2 Series gas transmitters. Other configurations are available for Class I, Division 2 applications. Hazardous-location approvals depend on the selected gas, sensor, and transmitter model. Verify the specific model certification before installation.
5. Can the RKI S2 Series be installed outdoors?
Yes. Applicable S2 transmitter configurations are designed for indoor or outdoor use. Optional splash guards are available for installations exposed to heavy moisture, and optional stainless steel junction boxes are available for corrosive environments.
6. What sensor technologies are available?
Depending on the gas being monitored, the S2 Series uses catalytic bead, infrared, galvanic cell, electrochemical, or metal oxide semiconductor sensing technology.
7. Can the RKI S2 Series connect to a PLC or DCS?
Yes. The S2 Series provides a 4–20 mA output and is designed to interface with compatible PLC and DCS systems, provided the electrical and signal requirements are met.
8. What is the difference between the RKI S2 and M2A-XL?
The S2 is a cost-effective fixed gas sensor/transmitter that provides a 4–20 mA output. The M2A-XL offers additional features, including an onboard digital gas concentration display, Modbus communication, and programmable alarm relays. The best choice depends on the application and monitoring requirements.
9. Does the RKI S2 Series require a separate gas monitoring controller?
The S2 can operate as a sensor/transmitter within an integrated gas monitoring system using a compatible controller, PLC, or DCS. It is not a standalone controller with its own complete alarm management system.
10. How do I select the correct RKI S2 gas sensor?
Select the sensor based on the target gas, required measuring range, installation environment, hazardous-location classification, and controller input requirements. Contact BuyGasMonitors.com for help selecting the appropriate RKI S2 Series configuration.
Buy RKI Instruments S2 Series Gas Sensors and Transmitters
Buy RKI Instruments S2 Series fixed gas sensors and transmitters from BuyGasMonitors.com. Choose from multiple gas detection configurations for industrial gas monitoring applications. Contact our team for assistance with sensor selection, controller compatibility, and application requirements.