RKI Instruments Introduces PPM Methane Range for the M2S Fixed Monitors
Posted by Bill Kimmell on 10th Sep 2018
RKI is now offering our Model M2A transmitter with a PPM range for methane detection. The M2A can monitor for 0 to 9,000 ppm methane with a resolution of 20 ppm.
This additional range means the M2A has the ability to monitor in the PPM, %
LEL, or
% volume ranges for methane. The M2A PPM Methane transmitter is now available
using the order information below.
To confirm if the ppm methane M2A is suitable for a given situation, please
discuss your application with TG Technical Services at 816-524-8100
65-2647RK | M2A, Methane (CH4) 0-9,000 ppm, sensor/transmitter with j-box |
1,025.00 |
65-2647RK-05 |
M2A,
Methane (CH4) 0-9,000 ppm, sensor/transmitter with j-box, |
1,075.00 |
CH4 0 - 9,000 PPM Specifications
Sensor: |
Catalytic |
Range: |
0 - 9,000 ppm |
Resolution: |
20 ppm |
Alarm 1: |
5,000 ppm |
Alarm 2: |
8,000 ppm |
Temperature Range: |
-40 - 75ºC |
Applications | M2A Features |
|
|